Hot
pellets coming from Pellet Mill are required to be cooled near
ambient temperature to remove moisture and heat to
improve the shelf life. Counter flow Coolers are fast
replacing the old Co-Flow or horizontal Coolers as these
are compact, maintenance free & highly efficient.
Principle:
- In Counter flow Coolers product continuously moves downward
direction in a bed of product in “first in first out
manner” while cool air passes through product in upward
direction. By the time product and air pass each other, they
exchange heat & moisture.
Construction:
- It is a rectangular chamber made of SS-304 construction
having an Air- Lock on top for entrance of material without
air escape and a triple-grid-gate for discharge of material.
A
stationary or rotating product distributor is installed to
evenly distribute the entering product over product bed. A
uniform bed height is maintained inside the chamber which can
be increased or decreased to control the retention time
by altering the position of level sensor which also initiates
discharging mechanism.
Atmospheric
air is sucked through the product layer by I. D. Fan which has
butterfly valve to control the optimum volume of air required
for cooling. Air can also be controlled by using a variable
frequency A.C. Drive by altering the RPM of Blower.
The
exhaust air is hot & moist and carries the dust particles
with it. Dust is removed from exhaust air by installation of a
Cyclone. This has an Air Lock below it. It works on
centrifugal forces.
It
is very essential to separate dust (fine feed) from exhaust air
to avoid shrinkage and air pollution. Properly designed
Cyclone with Air Lock at bottom will deliver clean air to
atmosphere.
|

|
Stationary
Product distributer
Evenly
distribution of pellets to maintain even bed height is
essential to avoid uneven cooling.
|
|

|
Butterfly
Valve is provided on I. D. Fan to control the optimum
volume of air required for effective cooling.
|
|
Level
Sensor can be adjusted up or down to control the height of bed
of pellets inside the cooling chamber to adjust the retention
time for moisture removal from the core of pellets and avoid
cooling shock.
|
|
Well
designed heavy duty I. D. Fan with dynamically balanced Rotor
|
|
| S.
No. |
Model |
Capacity
(tons/Hr.) |
Motor
Power |
I.D.
Fan's Motor Power |
| 1 |
LCFC
- 3 |
2-4 |
1
H.P. |
5 H.P. |
| 2 |
LCFC
- 6 |
5-7 |
1.5
H.P. |
10
H.P. |
| 3 |
LCFC
- 10 |
8-11 |
1.5
H.P. |
15
H.P. |
| 4 |
LCFC
- 15 |
14-16 |
2
H.P. |
20
H.P. |
|
|
|